Modern office meeting room with full-height framed glass demountable wall system

Demountable Wall System Guide

Responsible selection starts with the complete partition system: wall panels or glass, frames, tracks, connectors, joints, doors, hardware, seals, and floor, ceiling, and side interfaces.

What to Consider Before Selecting a System

Consider the complete system

Wall panels or glass, frames, tracks, connectors, joints, doors, hardware, seals, and floor, ceiling, and side interfaces.

Check project fit

Space use, openness and daylight, privacy, materials or equipment needs, acoustic, fire-related, and other project-specific performance requirements, initial budget priorities, site conditions, and expected future change.

Identify a preliminary system platform

Identify a preliminary SG platform based on wall thickness, configuration, and target performance.

Choose the wall configuration

Glass, solid panels, or a mixed configuration matched to daylight, privacy, and finish priorities.

Check doors, wall height, and building interfaces

Confirm door type, wall height, and the floor, ceiling, and side building interfaces before final selection.

Confirm performance targets and supporting evidence

Acoustic, fire, height, and stability targets matched to relevant reports, certificates, or test conditions.

Confirm project inputs and next steps

Confirm project inputs and next steps before moving from preliminary system direction to detailed coordination.

Compare Demountable Wall System Options

View the Demountable Wall System Guide

No single glass thickness, panel material, door choice, or SG platform name defines the complete system or determines the final project outcome.

Which Wall Route Fits the Project?

No single wall system suits every project. Start with space use, openness and daylight, visual privacy, material or equipment needs, acoustic, fire-related, and other project-specific performance requirements, initial budget priorities, site conditions, and expected future change.

Compare the SG platform options

When the project needs a coordinated non-load-bearing interior partition system, the next step is to compare the preliminary SG platform options.

Review the Demountable Wall System Guide

A Fixed-Wall Comparison May Make More Sense

When the layout is expected to remain stable or the main priority is the initial build rather than future reconfiguration.

Some Projects Need a Different Wall System

When the project involves load-bearing construction, an exterior façade, or a wall designed to slide, fold, or stack away during daily use.

Explore Types of Office Partitions

For the next step, note any required wall thickness or material preference, any performance requirement driving the decision, and any key information still missing.

Which SG Platform Should Be Compared First?

Wall thickness is only a starting point. The first comparison should also consider wall configuration, doors, height, interfaces, performance targets, and required evidence or supporting documents.

SG-40 slim single-glass demountable wall profile section

SG-40 for Slim, Visual-First Applications

An approximately 40 mm system mainly for regular single-glass applications.

View SG-40 Slim Glass Partition

SG-86 framed double-glass demountable wall profile section

SG-86 for Mainstream Framed Office Walls

An approximately 80–90 mm system for projects that may require double glass, integrated blinds, solid panels, mixed walls, or broader coordination of doors, seals, and visual privacy.

View SG-86 Framed Wall System

SG-100 steel-core demountable wall profile section with glass panels

SG-100 for Projects Requiring More Detailed Coordination

Consider this approximately 100 mm steel-core system when the proposed wall construction involves taller or more complex interfaces, selected door requirements, or fire-related, impact, or privacy requirements that need supporting documentation.

View SG-100 Steel-Core Wall System

When More Information Is Needed: confirm thickness, wall configuration, height, doors, performance targets, and evidence needs when any of these remain unclear or conflict with one another.

Which Wall Composition Fits the Space?

Choose glass, solid panels, or a mixed configuration based on daylight, privacy, finish, equipment needs, and SG-platform compatibility.

Glass wall configuration for daylight and visual connection in an office spac

Glass

Use glass where openness, daylight, and visual connection matter. Blinds provide adjustable privacy; frosting or graphics provide fixed screening while retaining a glass appearance.

Compare Glass Partition Systems

View Glass Partition Systems

Solid panel wall configuration with wood-look finish for visual privacy

Solid Panel

Use solid panels for fixed visual privacy, a defined finish, or functional wall zones. Confirm equipment locations and fixing points before finalizing the construction.

View Solid Demountable Partition Walls

Mixed glass and solid wall configuration for meeting room privacy and daylight

Mixed Glass + Solid

Combine glass and solid zones where daylight, privacy, finish, and equipment must be balanced. Coordinate their proportion and placement with elevation drawings, room use, and equipment layout.

Privacy and Equipment Check

Confirm display or cabinet location, weight, bracket, and fixing method; confirm socket, switch, and cable positions, routing, and access. Check whether backing or reinforcement is required. Visual screening does not prove speech privacy. Use elevation drawings and backing details to confirm placement and fixing. Request relevant reports or certificates for acoustic or fire requirements.

Could Door or Building Conditions Change the System Choice?

Yes. Doors, wall height, and building interfaces may confirm the initial choice or require a different platform or wall configuration.

When the Initial Choice Can Stay

A standard single-leaf door with a matching frame and routine hardware can usually remain with the initial choice when the floor, ceiling, and side conditions are straightforward.

When the Choice May Need to Change

Double-leaf, sliding, unusually tall, or specially framed doors may affect the frame, adjacent wall modules, hardware, or seals. Raised floors, curtain-wall connections, unusual side conditions, and special top support can also change the choice.

Confirm Early

Share any known special door, height, or interface conditions. Elevation or interface drawings can be reviewed where needed; complete connection details are not required for the first discussion. These conditions help determine the wall configuration, but they do not by themselves prove acoustic, fire, or stability performance.

Review Full-Height Glass Partition Requirements

Double-leaf door integrated into a demountable wall system with adjacent glass panels

Which Performance Requirements Need Deeper Review?

Demountable wall build-up showing glass panels, solid panels, frame profiles and insulation infill

Initial selection can identify a likely platform, wall composition, and areas requiring further confirmation. Defined acoustic, fire, height, stability, or documentation requirements need closer checking.

Initial Selection

  • General acoustic or privacy priorities
  • Likely wall, door, and sealing approach
  • Height or interface concerns

Review Acoustic Wall Partition System

Deeper Review

  • A defined acoustic target or test standard
  • A defined fire requirement or need for supporting documents
  • A full-height condition or unusual stability requirement
  • A report or certificate request

Review Fire-Rated Demountable Partition Walls
Compare NRC vs STC for Acoustic Performance

Test evidence applies only to the tested assembly, standard, and conditions, and must be matched to the proposed wall build-up. Drawings and component documentation support the item described but do not prove complete-wall performance. Past project results remain project-specific. Ask whether a relevant report or supporting document is available for the proposed wall configuration.

What Can the Preliminary Review Confirm?

A preliminary Onmuse review can identify a likely SG platform and wall configuration and show which details still need confirmation.

Preliminary DirectionWhat Still Needs ConfirmationNext Step
Likely SG platform and wall configurationConfiguration gaps or conflictsClarify the configuration
Door, hardware, height, and interface assumptionsMissing drawings or site conditionsReview drawings and interface conditions
Performance and document needsWhether the available evidence appliesCheck the evidence against the proposed configuration
Unusual project conditionsProject-specific technical questionsResolve the project-specific technical questions
Office workspace with full-height demountable glass walls and framed doors

What Should the Project Do Next?

The next step depends on what has already been confirmed and what the project needs now. Choose one path rather than preparing a complete technical package at the outset.

Narrow Down the System Choice

Use an initial system review when the SG platform, glass, solid, or mixed configuration, door requirements, or key project priorities still need to be compared.

View Demountable Wall System Resources

Coordinate the Drawings

Begin drawing or CAD coordination when the likely platform and wall configuration are clearer, but elevations, module layouts, door details, or building interfaces still need to be developed or confirmed.

Open Demountable Wall CAD / BIM Resources

Check Reports or Certificates

Request the relevant reports or certificates when an acoustic, fire-related, or other documented requirement must be checked against the proposed wall construction.

View Demountable Wall Certificates & Reports

Prepare a Formal Quotation

Proceed when dimensions, quantities, configuration, doors, finishes, and the main project conditions are sufficiently defined for a formal quotation.

Submit Drawings for a Formal Quotation

More details can be added as each path develops. Early system guidance is not a final design, engineering approval, performance guarantee, or binding quotation.