Start with the Acoustic Problem, Not the Metric
Focus first on what people are actually experiencing. Sound may pass through the partition or leak around the door bottom, frame, or perimeter gaps.
Reflections may also cause speech and noise to build up inside the room. In some spaces, both problems occur together. Hum, vibration, low-frequency noise, or structure-borne noise falls outside this basic split.
| Observed Problem | Problem Classification |
|---|---|
| Conversation is heard through the partition or around doors and perimeter gaps | Sound transmission concern |
| Speech and noise build up inside the room | Reflection / reverberation concern |
| Both are present | Combined concern |
| Hum, vibration, low-frequency noise, or structure-borne noise | Specialist acoustic issue |
Transmission and reflection may both matter in the same space, but they are different acoustic problems and should not be treated as the same issue.
NRC vs STC: What Each Metric Measures
STC describes how well a complete tested partition assembly resists airborne sound transmission. NRC describes how much sound a tested material or product absorbs when tested under a stated mounting condition. They answer different questions and cannot be converted, added, averaged, or combined into a single acoustic score.
| Comparison | STC | NRC |
|---|---|---|
| Main question | How well does the tested partition assembly resist airborne sound transmission? | How much sound does the tested material or product absorb? |
| Tested object | A complete tested partition assembly | A material or product tested under a stated mounting condition |
| Helps compare | Resistance to airborne sound transmission | Sound absorption performance |
| Does not prove | Low reverberation or the performance of the installed partition on site | Wall sound isolation or how reverberant the entire room will be |
A high NRC does not mean high sound isolation. A high STC does not mean low echo or reverberation inside the room.
Should You Focus on STC, NRC, or Both?
The right metric depends on what needs to improve. Airborne sound passing through a partition points to STC. Comparing how materials or products absorb sound points to NRC. When both sound transmission and in-room reflections are concerns, consider the two metrics separately. Hum, vibration, low-frequency noise, or structure-borne noise fall outside this basic comparison and require specialist acoustic input.
| Observed Need | Metric or Next Step |
|---|---|
| Reduce airborne sound passing through a partition | Focus on STC |
| Compare absorptive materials or products | Focus on NRC |
| Address both transmission and in-room reflections | Consider STC and NRC separately |
| Hum, vibration, low-frequency noise, or structure-borne noise | Seek specialist acoustic input |
NRC is used to compare absorptive materials or products under stated test and mounting conditions. It does not predict room reverberation on its own because room volume, absorptive surface area, placement, ceiling and floor finishes, furnishings, and room geometry also affect reverberation in the room.
STC and NRC answer different questions and should not be combined into one overall score.
How to Read an STC or NRC Report
The headline rating is not enough. Before using an STC or NRC result, check what was tested, how it was tested, under what conditions, and what the report actually covers. A report title or rating number does not replace checking the tested object and the report’s stated scope.
| Report Check | STC Report | NRC Report |
|---|---|---|
| Tested object | Tested partition assembly or specimen | Tested material or product |
| Construction details | Glass or panel build-up, frame, joints, seals, specimen details, and any door information identified in the report | Product type, thickness, and density where relevant |
| Test method | Test standard and classification method | Test standard or method |
| Installation condition | Laboratory or field test conditions, including any interfaces identified in the report | Mounting or installation conditions |
| Reported result | Rating stated in the report | Absorption result stated in the report |
| Identity and scope | Report number or other identification, tested specimen, and stated scope | Report number or other identification, tested product, and stated scope |
Technical relevance and report availability are separate questions. A report may be available, but its result may not apply to a different construction, product, mounting condition, or installation. A material or component result also does not automatically prove the performance of a complete wall assembly or an entire room.
Does the STC or NRC Result Apply to Your Partition?
A test result is relevant only when the proposed construction or product closely matches what was tested. A rating cannot be assumed when key details differ or remain unknown.
| Compare | Match | Difference | Unknown |
|---|---|---|---|
| Wall build-up and infill | Same materials and thicknesses | Build-up or infill differs | Not confirmed |
| Frame, joints, and seals | Same details as stated in the report | One or more details differ | Not stated |
| Door leaf and frame | Same door leaf and frame configuration as stated in the report | Door leaf or frame configuration differs | Door inclusion or details unclear |
| Mounting method and specimen dimensions | Same mounting method and dimensions | Method, conditions, or dimensions differ | Not reported |
The STC 42 result applies only to the tested 86T double-glazed laminated glass partition under laboratory conditions using ASTM E90 and ASTM E413. It does not represent every SG-86 system, every double-glazed partition, solid walls, other door configurations or wall constructions, complete rooms, or site results. The available information does not confirm the exact tested-door wording, frame type, or specimen dimensions.
Before using the rating for a proposed partition, Onmuse compares the proposed wall build-up, glazing, frame, joints, seals, door set, mounting method and dimensions with the tested assembly. Onmuse checks whether each item matches the tested assembly, differs from it, or still needs confirmation. Any key difference or missing detail means the same rating is not assumed.
Why Laboratory Ratings and Room Results Can Differ
A laboratory rating applies only to the tested construction and conditions. An installed partition or completed room may perform differently because sound can travel through openings, interfaces, and flanking paths outside the tested specimen.
| Result Level | What It Covers |
|---|---|
| Laboratory specimen | The construction and conditions included in the test |
| Installed partition | The installed wall, perimeter connections, and installation quality |
| Complete room | The partition, doors, ceiling, floor, openings, room surfaces, and flanking paths |
Ceiling plenums, raised floors, side walls, columns, service openings, perimeter gaps, and installation tolerances can affect the room result. Hard surfaces may also increase reflections, so sound absorption inside the room may need separate consideration.
In the Qatar Government Office Privacy Partition Project, the privacy requirement was considered together with the partition construction and its connections to surrounding building elements. This illustrates why a laboratory rating alone should not be used to predict the acoustic performance of a completed room.
Where to Go Next for Your Acoustic Requirement
Use the links below to check a proposed wall against relevant test evidence, request supporting documents, or obtain a project quotation.
| Buyer Need | Go To |
|---|---|
| Compare a proposed wall with relevant tested construction details | Acoustic Wall Partition System |
| Request a relevant test report or certificate | Request Test Reports and Certificates |
| Obtain pricing for a specific project | Office Partition Cost and Project Quotation Request |
Share the proposed wall and door details so the relevant test evidence can be checked. If you are interested in a specific product, you can request the relevant certificates and test reports. Contact our sales team for details.
Project pricing is based on the available project information rather than a fixed price list. A complete BOQ or final construction drawings are not required for the initial enquiry.